Temperature Shock Test Chamber

Availability:

Product application scope

The cold and thermal impact test box is suitable for the overall performance of various electronic parts, hardware and home appliances, plastic materials, automobiles, medical, chemical, communication and other industries products and materials in the rapid temperature change (normal temperature - high temperature - low temperature - normal temperature - low temperature - normal temperature) environment. It is suitable for product development, design, production, inspection and other departments of temperature and humidity environment testing in various industries.

Using 7 inches of Chinese and English display color touch screen screen, simple operation, easy program editing, can display the complete system operation status related data, implementation and setting program curve. When an abnormal situation occurs during operation, the screen automatically displays the cause of the fault immediately and provides troubleshooting methods

Dimensions of the inner and outer boxes

Inner box size: wide 500x deep 500X height 400mm

Outer box size: width 1400x depth 1900X height 1950

Inner box volume: 100L

About weight: 300kg

The box corner contains 4 universal corners and is mobile

Performance parameter index

high-temperature cabinet

(1) Temperature range: + 60℃ ~ + 220℃

(2) Heating rate: 14℃ / min

cryogenic box

(1) Temperature range: -80℃ ~70℃

(2) Temperature increase rate: 2℃ min

(3) Cooling rate: 5℃ min

Pilot zone (hanging blue)

(1) High temperature exposure temperature range: + 60℃ ~ + 200℃

(2) Low temperature exposure temperature range: -70℃ ~70℃

Impact temperature range

-55℃~150℃

recovery time

Endovirus within 5 minutes

change-over time

10 Seconds

Sample load

The load of 5kg

temperature uniformity

≤2℃

temperature fluctuation

±0.5℃

temperature departure

±2℃

Hanging bar movement time

Reset within 10 seconds from high temperature slot to low temperature slot

Expose time

10min

Hanging column structure

The product to be tested is mobile, and the cylinder drive crane moves up and down

Compressor freezing mode

Water-cooled type, without water chiller and water road installation

satisfying criteria

The DLT series of products can meet the following standards

GB-2423.1-89 (IEC68-2-1) Test A: Test method at low temperature.(cold-resistant)

GB-2423.2-89 (IEC68-2-2) Test B: High temperature test method.(dry heat)

GJB150.3-86 GJB150.4-86 (MIL-STD-810D)

GB10589-89, Technical conditions of the high and low temperature test box

GB/T2423.22-02/-87 Test N: Test method for temperature change

Thermal shock test chamber standard:

1. Test box test standard

1)GB/T 2423.22-2012 - Part 2: Test methods Test N: temperature change;

2)IEC 60068-2-14-2009 Environmental tests-Part 2-14 Test N Temperature change;

3)GJB 150.5A-2009 temperature impact test;

4)GJB 360B-2009 Test method for electronic and electrical components.

2. The performance of the test box is confirmed to meet the standard

1)GB/T2424.5-2006 Electrical and electronic products environmental test temperature test chamber performance confirmation;

2)GB/T5170.2-2008 electronic and electrical products environmental test equipment inspection method + temperature test equipment;

JJF1101-2003 Calibration specification for temperature and humidity of environmental test equipment

Thermal shock test chamber features:

1. The three-box type hot and cold impact test chamber is divided into three parts: high temperature area, test area and low temperature area. The product to be tested is placed in the test area.

2. Using 7 inches in Chinese and English to display color touch screen screen, simple operation, easy program editing, can display the complete system operation status related data, implementation and setting program curve (as shown on the right). When an abnormal situation occurs during operation, the screen automatically displays the cause of the fault immediately and provides troubleshooting methods.

3. Shock mode The air duct is switched to import the temperature into the test area for cold and hot shock test.

4. When high temperature impact or low temperature impact, single time and cycle impact number can be set, the maximum time of a single time can reach 999H, and the maximum cycle can reach 9999 times.

5. In order to reduce the energy waste and consumption of hot and cold shock, our company technically introduces the servo control technology of refrigerant flow opening and adopts advanced long-term frost exemption patent technology, which effectively reduces the number and time required for defrost; Different from the old cold and heat shock machine, it needs to be defrosted every 10 to 20 cycles. In practical use, according to the lead-free process test conditions to set, it is necessary to perform at least 1000 cycles, and perform 50 defrosting, and each defrosting takes two hours, which is equivalent to wasting 100 hours (about 4 days) of test time and electricity.

Safety protection device:

1. Short circuit and leakage protection;

2. Motor over-temperature, over-current protection;

3. Power reverse phase and undersequence protection;

4. Compressor overheating, overcurrent, high pressure protection;

5. Heater short circuit, overtemperature, overcurrent protection;

6. Water tank warning;

7. Line fully sheathed terminals.

Detail presentation

微信图片_20231207161641副本副本微信图片_20231207121832 (2)微信图片_20231211085445副本微信图片_20231207121853微信图片_20231207121758副本

Previous: 
Next: 

 Shenzhen Shenguangxin Technology Co., Ltd. is in conformity with Quality Management System Standard: GB/T 19001-2016/ISO9001:2015

QUICK LINKS

PRODUCT CATEGORY

CONTACT US
 Tel: +86-158-1862-4714
 E-mail: service@mail.com
 Address: 402, Building A, Huaqiang Building, Heshuikou New Village, Guangming District, Shenzhen City, Guangdong Province
Subscribe

 Shenzhen Shenguangxin Technology Co., Ltd. is in conformity with Quality Management System Standard: GB/T 19001-2016/ISO9001:2015